  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
R408LS
8 – 5
1) In connection with pads.
a) When touching the pads, a certain group of pads do not produce a signal.
b) When touching the pads, no pads produce a signal.
2) In connection with indicators
a) At a certain digit, all or some segments do not light up.
b) At a certain digit, brightness is low.
c) Only one indicator does not light.
d) The corresponding segments of all digits do not light up; or they continue to light up.
e) Wrong figure appears.
f) A certain group of indicators do not light up.
g) The figure of all digits flicker.
3) Other possible problems caused by defective control unit.
a) Buzzer does not sound or continues to sound.
b) Clock does not operate properly.
c) Cooking is not possible.
3. If the Key unit or the Control unit is defective.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Replace the Control unit assembly.
5) Reconnect all leads removed from components during testing.
6) Reinstall the outer case (cabinet).
7) Reconnect the power supply cord after the outer case is installed.
8) Run the oven and check all functions.
4. When testing is completed,
1) Disconnect the power supply cord and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Reconnect all leads removed from components during testing.
5) Reinstall the outer case (cabinet).
6) Reconnect the power supply cord after the outer case is installed.
7) Run the oven and check all functions.
[12] K: KEY UNIT TEST
If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable is making good contact, verify that the door sens-
ing switch (stop switch) operates properly; that is the contacts are closed when the door is closed and open when the door is open. If the door sensing
switch (stop switch) is good, disconnect the flat ribbon cable that connects the key unit to the control unit and make sure the door sensing switch is
closed (either close the door or short the door sensing switch connector). Use the key unit matrix indicated on the control panel schematic and place
a jumper wire between the pins that correspond to the STOP/CLEAR pad making momentary contact.If the control unit responds by clearing with a
beep the key unit is faulty and must be replaced. If the control unit does not respond, it is faulty and must be replaced. If a specific pad does not
respond, the above method may be used (after clearing the control unit) to determine if the control unit or keypad is at fault.
[13] L: RELAY TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
G5 G4 G3G8
G10
G11
G12
G13
NC
G7 G6
G9
G2 G1
REHEAT
4
1
7
2
5
8
0
TIMER
CLOCK
6
3
9
COOK
SOFTEN MELT
WARM
POPCORN
DEFROST
POWER
LEVEL
STOP
CLEAR
START
MINUTE
PLUS