LD-22Z03D- 18
11Packing form
11Packing form11Packing form
11Packing form
a) Piling number of cartons : MAX.5
b) Package quantity in one carton: 5pcs
c) Carton size(TYP): 493mm(W) × 417mm(D)×293mm(H)
d)
Total mass of one carton filled with full modules(5pcs): 15kg
12Reliability test items
12Reliability test items12Reliability test items
12Reliability test items
△2 △3
No.
1
2
3
4
5
6
7
8
【Note1】 Under the display quality test conditions with normal operation state, these shall be no change
which may affect practical display function. (normal operation state:Temperature:15~35℃,
Humidity:45~75%, Atmospheric pressure:86~106kpa)
Electrostatic
discharge test
(non-operating)
【Note1】
Vibration test
(non-operating)
【Note1】
Shock test
(non-operating)
【Note1】
 <Sin wave>
  Frequency :10~57Hz/Vibration width (one side) :0.076mm
     :57~500Hz/Gravity:9.8m/s2
  Sweep time:11minutes
 Test period :3H(X,Y,Z direction 1H)
Max. gravity:490m/s2 Pulse width:6ms
 Direction:±X,±Y,±Z Test period :1time/1direction
Contact discharge (150pF 330Ω):
non-operation=±10kV, operation=±8kV
Aerial discharge (150pF 330Ω):
non-operation=±20kV, operation=±15kV
【Note1】
Low temperature
operation test
【Note1】
High temperature
operation test
 Panel surface 65℃ 240H
 Ambient temperature 0℃ 240H
【Note1】
【Note1】
Remark
【Note1】
Conditions
 Ambient temperature 65℃ 240H
Low temperature
strage test
High temperature
& high humidity
operation test
Test item
High temperature
storage test
 Ambient temperature -25℃ 240H
 Ambient temperature 40℃、Humidity 95% RH 240H
(No condensation.)