Replace both lamps, take out the lamp replaced first and refit it. Provided
lamp and ECG are o.k. both lamps should then light.
2.5.1 Lamp ignition for QTi
Lamp start Preheat
Ignition time < 1 second
Max. number of switching cycles > 100,000 cycles
2.5.2 Lamp ignition for QT
to operate T5-
fluorescent lamps
QT-FH MULTI, QT-FQ, QT…F/CW
Lamp start Preheat
Ignition time < 0.5 second
Max. number of switching cycles > 100,000 cycles
2.5.3 Off- Time for
Optimum Preheat
Start
All QUICKTRONIC to operate T5/ 16 mm- fluorescent lamps
FH
®
…HE, FQ
®
…HO and FC start the lamps at any time with optimum
preheat start even after a turn-off followed by an immediate lamp
restart. OSRAM QUICKTRONIC ignite the lamp always with optimum
preheating of the electrodes. A particular off-time with regards to
lamp life is not necessary.
2.6 Behaviour in Response
to Lamp Defects
What do we mean by lamp defect or end-of-lamp life?
In most cases, it is not possible to see from outside which lampholders are
assigned to which ECG-terminals, so if you insert lamps and they fail to
start automatically you should take out the first lamp again and refit it. Both
lamps should then light.
Lamp replacement of 2- and multilamp luminaires proceed as follows:
Insert the lamps. If at 2- or multilamp luminaires lamp ignition doesn’t work
automatically, take out the lamp replaced first and refit it. Reignition of both
lamps works automatically.
2.6.1 One-Lamp Operation
with Multi-Lamp ECG
What are the requirements?
Parallel Circuitry Series Circuitry
UU
Start
UU
Start
QTP 2x...
I
L
I
L
I
L
I
L
QT
-
FQ 2x...
I
L
U
Zünd
I
L
QT
-
FQ 2x...
I
L
I
L
U
Start
I
L
I
L