ROOM AIR CONDITIONER
INSTALLATION AND OPERATION
MANUAL
PAGE
CONTENTS
This INSTALLATION AND OPERATION
MANUAL explains the proper use of your new
Sharp Air Conditioner. Read these instructions
carefully before installing or operating your air
conditioner. The INSTALLATION AND OP-
ERATION MANUAL should be kept in a safe
place for handy reference.
FOR YOUR PROTECTION.................... 2
CONSUMER LIMITED WARRANTY ..... 3
INSTALLATION INSTRUCTIONS
• CHECK WINDOW AREA ........................ 4
• LOCATlON .............................................. 4
• ITEMS PACKED WITH THlS UNIT ......... 5
• SUGGESTED TOOLS ............................ 5
• INSTALLATION....................................... 5
PRECAUTIONS
CAUTION FOR USE ............................ 8
• GROUNDING INSTRUCTIONS ........... 8
• NOTES ON OPERATION .................... 9
• ENERGY EFFICIENCY TIPS ............... 9
HOW TO OPERATE
• PARTS NAMES ...................................10
COOLING OPERATION ...................... 11
• TO CHANGE FAN SPEED AND
OPERATION MODE.......11
TO CHANGE TEMPERATURE SETTING ..........
12
TO CHANGE AIR FLOW DIRECTION .......
12
• EXHAUST ............................................12
• ENERGY SAVER OPERATION ........... 13
• SLEEP OPERATION ...........................13
• ON TIMER OPERATION .....................14
• OFF TIMER OPERATION .................... 15
• USING THE REMOTE CONTROL ....... 16
CLEANING AND MAINTENANCE ........ 18
BEFORE CALLING FOR SERVlCE ...... 19
AF-S100EX
AF-S120EX
AF-S125EX
AF-R100EX
AF-R120EX
As an ENERGY STAR Partner, Sharp Electronics has determined that these products (AF-S100EX, AF-
S120EX, AF-S125EX) meet the ENERGY STAR guidelines for energy efficient air conditioners. To meet
these guidelines, air conditioners must be at least 10% more efficient than the minimum Federal standard.
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - AF-R120EX

ROOM AIR CONDITIONERINSTALLATION AND OPERATION MANUALPAGECONTENTSThis INSTALLATION AND OPERATIONMANUAL explains the proper use of

Page 2 - FOR YOUR PROTECTION

1091212345 6 71310118UNITCONTROL PANELHOW TO OPERATEFront panelAir inlet (Indoor side)Vertical louversHorizontal louversAir outlet (Indoor side)Exhau

Page 3 - CONSUMER LIMITED WARRANTY

11HOW TO OPERATECooling operation with high fan speed.Cooling operation with medium fan speed.Cooling operation with low fan speed.Fan only operation

Page 4 - INSTALLATION INSTRUCTIONS

12HOW TO OPERATE---Lower temp.Touch the TEMPERATURE settingpad to adjust the temperature set-ting.• Temperature can be set within the rangeof 64°F to

Page 5 - INSTALLATION

13HOW TO OPERATEENERGY SAVER OPERATIONDuring normal operation, the thermostat automatically controls cooling and the fan runs continu-ously. When the

Page 6

14HOW TO OPERATEON TIMER OPERATION(If you wish to start the operation6 hours and 30 minutes later, setthe delay time as shown above.)1Touch the TIMER

Page 7

15HOW TO OPERATEOFF TIMER OPERATION• This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance.You can set

Page 8 - PRECAUTIONS

16HOW TO OPERATEOpen the battery compartmentcover.Insert and slide the batteries intothe compartment, making surethe and polarities arepro

Page 9 - NOTES ON OPERATION

17HOW TO OPERATEOPERATING WITH THE REMOTE CONTROL• The time setting will change as you push the button. The displaywill change as follows;TEMP.TEMP.-

Page 10 - HOW TO OPERATE

18ENERGY EFFICIENCY TIPSCLEANING AND MAINTENANCECLEANING THE FILTERIf the filter is clogged with dust, the amount of air flow willbe reduced, resultin

Page 11 - COOLING OPERATION

19BEFORE CALLING FOR SERVlCEIF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECKTHE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE.AIR CONDITIO

Page 12 - TO CHANGE AIR FLOW DIRECTION

2To aid in answering questions if you call for service or for reporting loss or theft, please recordbelow the model and serial number located on the r

Page 13 - SLEEP OPERATION

20 SHARP ELECTRONICS CORPORATIONSharp Plaza, Mahwah, New Jersey 07430-2135SHARP CORPORATIONOsaka, JapanPrinted in Thailand

Page 14 - ON TIMER OPERATION

3SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"),when shipped in its o

Page 15 - OFF TIMER OPERATION

4INSTALLATION INSTRUCTIONSBefore beginning installation, read these instructions carefully.Use the enclosed MOUNTING KIT for proper installation.The m

Page 16 - USING THE REMOTE CONTROL

5No.AccessoriesQ'tyRight closure assemblyLeft closure assemblyWindow sash foam seal1111. Screw driver (medium size Phillips)2. Tape measure o

Page 17

6INSTALLATION INSTRUCTIONSOpen the window sash and place thecabinet on the sill.Close the window sash securely behindthe top angle.If there

Page 18 - CLEANING AND MAINTENANCE

7INSTALLATION INSTRUCTIONSClosure assembly(Left)8Jamb(Left)Top angleSill1/2 inch (13mm)Closure assembly(Left)StoolInsert the closure assemblies o

Page 19 - BEFORE CALLING FOR SERVlCE

8IMPORTANT: Points to keep in mind when using your air conditioner.• Install the air conditioner by following the installation instructions given in t

Page 20 - Osaka, Japan

9PRECAUTIONS•Allow 3 minutes for the compressor to restart cooling.If you turn the air conditioner off and immediately restart it, allow three minutes