Sharp XE-A402 Service Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 25
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
PC-UM10M
XE-A402 HARDWARE DESCRIPTION
– 9 –
5-3. KEYSCAN MATRIX
PENDING
Others
5-4. DISPLAY (PENDING)
The A401 has an LCD display, 5 x 7 dots, 2 lines, at the front side and a
7-digit LED at the pop-up side.
• Display DIGIT signal
The above ST0 ~ ST6 are display digit signals.
ST0: 1st digit ~ ST6: 7th digit
Display SEGMENT signal
The LED segment signal is outputted by writing SEGMENT data in
the /CS3 space.
Correspondence of DATA ~ SEGMENT
D0 ~ D6
3
A ~ g
D7
3
DP
6. POWER SUPPLY
7. REWRITING FLASH MEMORY
IPL from EP-ROM:
After IPL SW is set to ONA the program is started
from EP-ROM by turning on the power.
The program on EP-ROM is transferred to flash
ROM by switching the banks through S-RAM.
IPL from COM:
Data from the PC is written to flash ROM through
the COM port. (Max. 38.4 kbps)
8. DRAWER
The A401 has a 1 channel of drawer port. (+ 1 channel is reserved for
the CPU PORT) O R No open sensor is provided.
The driving time for the DRAWER solenoid are as follows: 50ms (max)
45ms (min)
9. PRINT RATE
384 dots/1 line
10. A/D CONVERSION
The printer power supply voltage should be measured at more than 10
ms after the printer is turned ON.
11. BUZZER
PIEZO type BUZZER
The oscillating frequency is 4.0kHz
m
0.5kHz
12. RESET
The RESET signal is generated when:
1) The mode key switch is turned from SRV to a position other than
SRV’(excluding OFF).
2) The power is turned ON more than 10 seconds after the power is
turned OFF. (The reset signal may not be issued if the POWER-
OFF time is short.)
3) The mode key switch is turned from OFF to a position other than
OF (excluding the SRV position). (If the power-off time is less than 5
seconds, the reset signal may not be issued.)
CPU STO ST1 ST2 ST3 ST4 ST5 ST6 ST7 ST8 ST9
MODE P90 SRV PGM Time REG MGR X1/Z1 X2/Z2
Others P91 PF-R PF-J RPE HEAD
UP
JPE DRAWER
OPEN
MRS RS/CI
FRONT:
POP UP:
VCC 5.0V
24V
BATTERY
/POFF detection
point
TRANS.
LM2574 +
power failure occurs..
PQ1CG2032
ON/OFF CONTROL
(MODE SW)
Measures should be taken to restore within 10 ms after a
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 24 25

Comments to this Manuals