6.
7.
Disconnect the two connectors to take out the CCD
PWB.
Each connector has four wires.
(For 40U, disconnect the three connectors.)
Remove the one screw ((b)LX-HZ0050TAFF) and
disconnect the connector to take out the top cabinet.
8. Remove the four screws ((f)XiPSF17P03000)
to take out the AV jack PWB and strobe unit.
Caution:
Hold the transformer to remove the strobe unit.
CCD PWB
Connector(CG40U only)
Connector
Connector
b
Connector
AV jack PWB
Strobe unit
Transformer
Prepare approx. 5k/5W.
Figure 1
Clip
+
-
High voltage section
Clip connection
Caution: Electric shock
When disassembling or repairing the set, do not touch the high voltage section of the main capacitor
since it contains high voltage. Be especially careful when removing and mounting the screws of the jack
unit (DUNTKB359PM) and strobe unit as well as when replacing the wires (QCNW-A562/564/565WJ).
After removing the strobe unit, prepare the following discharging jig (1) and connect it to the (2) position
as shown in the figure. Discharge main capacitor by leaving discharge jig attached for 60 seconds.